FED-STD-791D
6. PROCEDURE
6.1 Clean the jar and cap by scrubbing with scouring powder and rinsing with tap
water. Complete the rinsing with distilled water, and air dry the jar and cap (using an
oven at 104C if desired).
6.2 Line the cap with aluminum foil.
6.3 Pour approximately 3.8 L of the sample into the jar, and replace and tighten
the cap.
6.4 Wrap aluminum foil around the jar to exclude all light from the sample.
6.5 Identify the contents of the glass jar (including type of sample, date stored,
and any other useful information).
6.6 Store the sample for one year in the storage chamber 24 " 3C (75 " 5F).
6.7 At the end of the 12-month period, remove the jar from the chamber and take
off the aluminum wrapper, being careful not to shake or agitate the contents.
6.8 Visually examine the sample, and note the presence of cloudiness, sediment,
suspended matter, discoloration, or other changes in homogeneity.
7. CALCULATIONS
7.1 This section is not applicable to the test procedure.
8. REPORTING
8.1 Report the presence of cloudiness, sediment, suspended matter, discoloration,
or other changes in homogeneity.
9. PRECISION
9.1 Precision data have not been developed for this method.