FED-STD-791D
Method 3710.1
September 30, 1986
MOLYBDENUM DISULFIDE PURITY
1. SCOPE
1.1 This method is used for determining the purity of molybdenum disulfide
powder.
2. SUMMARY
2.1 This method consists of dissolving the MoS2 in nitric acid and perchloric
acid, removing iron with ammonium hydroxide and precipitating solution with lead
acetate. The purity of MoS2 is determined from the weight of lead molybdate precipitate.
3. SAMPLE SIZE
3.1 10 g of molybdenum disulfide (MoS2) powder.
4. REFERENCES, STANDARDS, AND APPARATUS
4.1 Hot plate.
4.2 Beakers, borosilicate, 400 and 600 mL.
4.3 Pipet, 50 mL.
4.4 Volumetric flask, 500 mL.
4.5 Buret, 50 mL.
4.6 Mechanical stirrer.
4.7 Porcelain crucible.
4.8 Muffle furnace capable of maintaining 550 to 600C (1,020 to 1,110F).
4.9 Desiccator.
4.10 Analytical balance.