FED-STD-791D
Method 5414.4
September 30, 1986
RESISTANCE OF GREASE TO FUEL
1. SCOPE
1.1 This method is used for determining the resistance of grease to the solvent
action of fuel.
2. SUMMARY
2.1 The test consists of determining the solubility of the grease in a standard test
fluid, and observing for physical changes caused by an 8-hour immersion in the test fluid.
3. SAMPLE SIZE
3.1 Approximately 4 g of grease to be tested (duplicate 2 g samples).
4. REFERENCE, STANDARDS, AND APPARATUS
4.1 Centrifuge, approximately 650 rpm, swing diameter (tip to tip of whirling
tubes) approximately 40 cm, or equivalent.
NOTE: An equivalent centrifuge must be capable of having its speed adjusted
according to the following formula:
40
rpm =
* 650
d
where:
d = diameter (tip to tip) of whirling tubes centimeters
4.2 Shaker, mechanical, stroke approximately 3.8 cm (1-1/2 in), speed
approximately 1350 rpm.
4.3 Centrifuge tube, 200 mL, with stopper.
4.4 Evaporation dish, 100 mL.
4.5 Pipet, 50 mL.