FED-STD-791D
6. PROCEDURE
6.1 Fill the fluid cylinder of the spray test setup with test fluid at 15.6 to 37.8C
(60 to 100F) and adjust nitrogen pressure to produce a liquid pressure of 6894 " kPa
gage (1000 " 10 psig).
6.2 Adjust the torch to deliver a neutral flame.
6.3 Open the quick-opening valve at the orifice and attempt to ignite the spray
with the torch at the nozzle.
6.4 If the spray does not ignite gradually move the torch away from the nozzle
until ignition takes place (45.7 cm max.)
7. CALCULATIONS
7.1 This section is not applicable to the test procedure.
8. REPORTING
8.1 Report whether the spray ignites. If the spray does ignite, also report:
a. The distance from torch to nozzle at ignition.
b. Whether the spray flashes readily or with difficulty.
c. Whether the flame produced is self extinguishing or sustained.
9. PRECISION
9.1 Precision data have not been developed for this method.