FED-STD-791D
6. PROCEDURE
6.1 Clean the outside surface of the tube of the test setup (Figure 1), using steel
wool.
6.2 Mount the heating element centrally in the tube, and adjust the voltage so that
the temperature of the tube is maintained at 704C (1300F).
6.3 When the tube has reached the correct temperature, drop 10 mL portions of
the test liquid at a rate of 10 mL in 40 to 60 s from various heights onto various points on
the tube, and observe the ignition characteristics of the liquid. (Clean the tube with steel
wool before each 10 mL application of the liquid.)
7. CALCULATIONS
7.1 This section is not applicable to the test procedure.
8. REPORTING
8.1 Report results as follows:
a. Flashes or burns on the tube, but does not after dripping from the tube.
b. Does not flash or burn on tube, but does after dripping from the tube.
c. Does not flash or burn on the tube or after dripping from the tube.
9. PRECISION
9.1 Precision data have not been developed for this method.
Method prepared by:
Army - ME - 1986